Filename: zcl_hvac.h
|
|||
|
Revised: $Date: 2011-05-19 11:53:12 -0700 (Thu, 19 May 2011) $
|
|||
|
Revision: $Revision: 26031 $
|
|||
|
|
|||
|
Description: This file contains the ZCL HVAC definitions.
|
|||
|
|
|||
|
|
|||
|
Copyright 2006-2011 Texas Instruments Incorporated. All rights reserved.
|
|||
|
|
|||
|
IMPORTANT: Your use of this Software is limited to those specific rights
|
|||
|
granted under the terms of a software license agreement between the user
|
|||
|
who downloaded the software, his/her employer (which must be your employer)
|
|||
|
and Texas Instruments Incorporated (the "License"). You may not use this
|
|||
|
Software unless you agree to abide by the terms of the License. The License
|
|||
|
limits your use, and you acknowledge, that the Software may not be modified,
|
|||
|
copied or distributed unless embedded on a Texas Instruments microcontroller
|
|||
|
or used solely and exclusively in conjunction with a Texas Instruments radio
|
|||
|
frequency transceiver, which is integrated into your product. Other than for
|
|||
|
the foregoing purpose, you may not use, reproduce, copy, prepare derivative
|
|||
|
works of, modify, distribute, perform, display or sell this Software and/or
|
|||
|
its documentation for any purpose.
|
|||
|
|
|||
|
YOU FURTHER ACKNOWLEDGE AND AGREE THAT THE SOFTWARE AND DOCUMENTATION ARE
|
|||
|
PROVIDED <EFBFBD>AS IS<EFBFBD> WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED,
|
|||
|
INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, TITLE,
|
|||
|
NON-INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL
|
|||
|
TEXAS INSTRUMENTS OR ITS LICENSORS BE LIABLE OR OBLIGATED UNDER CONTRACT,
|
|||
|
NEGLIGENCE, STRICT LIABILITY, CONTRIBUTION, BREACH OF WARRANTY, OR OTHER
|
|||
|
LEGAL EQUITABLE THEORY ANY DIRECT OR INDIRECT DAMAGES OR EXPENSES
|
|||
|
INCLUDING BUT NOT LIMITED TO ANY INCIDENTAL, SPECIAL, INDIRECT, PUNITIVE
|
|||
|
OR CONSEQUENTIAL DAMAGES, LOST PROFITS OR LOST DATA, COST OF PROCUREMENT
|
|||
|
OF SUBSTITUTE GOODS, TECHNOLOGY, SERVICES, OR ANY CLAIMS BY THIRD PARTIES
|
|||
|
(INCLUDING BUT NOT LIMITED TO ANY DEFENSE THEREOF), OR OTHER SIMILAR COSTS.
|
|||
|
|
|||
|
Should you have any questions regarding your right to use this Software,
|
|||
|
contact Texas Instruments Incorporated at www.TI.com.
|
|||
|
**************************************************************************************************/
|
|||
|
|
|||
|
#ifndef ZCL_HVAC_H
|
|||
|
#define ZCL_HVAC_H
|
|||
|
|
|||
|
#ifdef __cplusplus
|
|||
|
extern "C"
|
|||
|
{
|
|||
|
#endif
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
* INCLUDES
|
|||
|
*/
|
|||
|
#include "zcl.h"
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
* CONSTANTS
|
|||
|
*/
|
|||
|
|
|||
|
/**************************************************************************/
|
|||
|
/*** HVAC: Pump Config and Control Cluster Attributes ***/
|
|||
|
/**************************************************************************/
|
|||
|
// Pump information attribute set
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_PRESSURE 0x0000
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_SPEED 0x0001
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_FLOW 0x0002
|
|||
|
#define ATTRID_HVAC_PUMP_MIN_CONST_PRESSURE 0x0003
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_CONST_PRESSURE 0x0004
|
|||
|
#define ATTRID_HVAC_PUMP_MIN_COMP_PRESSURE 0x0005
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_COMP_PRESSURE 0x0006
|
|||
|
#define ATTRID_HVAC_PUMP_MIN_CONST_SPEED 0x0007
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_CONST_SPEED 0x0008
|
|||
|
#define ATTRID_HVAC_PUMP_MIN_CONST_FLOW 0x0009
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_CONST_FLOW 0x000A
|
|||
|
#define ATTRID_HVAC_PUMP_MIN_CONST_TEMP 0x000B
|
|||
|
#define ATTRID_HVAC_PUMP_MAX_CONST_TEMP 0x000C
|
|||
|
// Pump Dynamic Information attribute set
|
|||
|
#define ATTRID_HVAC_PUMP_STATUS 0x0010
|
|||
|
#define ATTRID_HVAC_PUMP_EFECTIVE_OPERATION_MODE 0x0011
|
|||
|
#define ATTRID_HVAC_PUMP_EFFECTIVE_CONTROL_MODE 0x0012
|
|||
|
#define ATTRID_HVAC_PUMP_CAPACITY 0x0013
|
|||
|
#define ATTRID_HVAC_PUMP_SPEED 0x0014
|
|||
|
#define ATTRID_HVAC_PUMP_LIFETIME_RUNNING_HOURS 0x0015
|
|||
|
#define ATTRID_HVAC_PUMP_POWER 0x0016
|
|||
|
#define ATTRID_HVAC_LIFETIME_ENERGY_CONSUMED 0x0017
|
|||
|
/*** Pump status attribute values ***/
|
|||
|
#define HVAC_PUMP_DEVICE_FAULT 0x0000
|
|||
|
#define HVAC_PUMP_SUPPLY_FAULT 0x0001
|
|||
|
#define HVAC_PUMP_SPEED_LOW 0x0002
|
|||
|
#define HVAC_PUMP_SPEED_HIGH 0x0003
|
|||
|
#define HVAC_PUMP_LOCAL_OVERRIDE 0x0004
|
|||
|
#define HVAC_PUMP_RUNNING 0x0005
|
|||
|
#define HVAC_PUMP_REMOTE_PRESSURE 0x0006
|
|||
|
#define HVAC_PUMP_REMOTE_FLOW 0x0007
|
|||
|
#define HVAC_PUMP_REMOTE_TEMPERATURE 0x0008
|
|||
|
// Pump Settings attributes set
|
|||
|
#define ATTRID_HVAC_PUMP_OPERATION_MODE 0x0020
|
|||
|
#define ATTRID_HVAC_PUMP_CONTROL_MODE 0x0021
|
|||
|
#define ATTRID_HVAC_PUMP_ALARM_MASK 0x0022
|
|||
|
//#define ATTRID_HVAC_PUMP_CAPACITY_MIN_PERCENT_CHANGE 0x0023
|
|||
|
//#define ATTRID_HVAC_PUMP_CAPACITY_MIN_ABSOLUTE_CHANGE 0x0024
|
|||
|
/*** Operation mode attribute values ***/
|
|||
|
#define HVAC_PUMP_OPERATION_MODE_NORMAL 0x00
|
|||
|
#define HVAC_PUMP_OPERATION_MODE_MINIMUM 0x01
|
|||
|
#define HVAC_PUMP_OPERATION_MODE_MAXIMUM 0x02
|
|||
|
#define HVAC_PUMP_OPERATION_MODE_LOCAL 0x03
|
|||
|
/*** Control mode attribute values ***/
|
|||
|
#define HVAC_PUMP_CONTROL_MODE_CONSTANT_SPEED 0x00
|
|||
|
#define HVAC_PUMP_CONTROL_MODE_CONSTANT_PRESSURE 0x01
|
|||
|
#define HVAC_PUMP_CONTROL_MODE_PR0PORTIONAL_PRESSURE 0x02
|
|||
|
#define HVAC_PUMP_CONTROL_MODE_CONSTANT_FLOW 0x03
|
|||
|
#define HVAC_PUMP_CONTROL_MODE_CONSTANT_TEMPERATURE 0x05
|
|||
|
#define HVAC_PUMP_CONTROL_MODE_CONSTANT_AUTOMATIC 0x07
|
|||
|
/*** Alarm Mask attribute values ***/
|
|||
|
#define HVAC_PUMP_SUPPLY_VOLTAGE_TOO_LOW 0x0001
|
|||
|
#define HVAC_PUMP_SUPPLY_VOLTAGE_TOO_HIGH 0x0002
|
|||
|
#define HVAC_PUMP_POWER_MISSING_PHASE 0x0004
|
|||
|
#define HVAC_PUMP_SYSTEM_PRESSURE_TOO_LOW 0x0008
|
|||
|
#define HVAC_PUMP_SYSTEM_PRESSURE_TOO_HIGH 0x0010
|
|||
|
#define HVAC_PUMP_DRY_RUNNING 0x0020
|
|||
|
#define HVAC_PUMP_MOTOR_TEMPERATURE_TOO_HIGH 0x0040
|
|||
|
#define HVAC_PUMP_MOTOR_HAS_FATAL_FAILURE 0x0080
|
|||
|
#define HVAC_PUMP_ELECTRONIC_TEMPERATURE_TOO_HIGH 0x0100
|
|||
|
#define HVAC_PUMP_BLOCKED 0x0200
|
|||
|
#define HVAC_PUMP_SENSOR_FAILURE 0x0400
|
|||
|
#define HVAC_PUMP_ELECTRONIC_NON_FATAL_FAILURE 0x0800
|
|||
|
#define HVAC_PUMP_ELECTRONIC_FATAL_FAILURE 0x1000
|
|||
|
#define HVAC_PUMP_GENERAL_FAULT 0x2000
|
|||
|
// Pump Unit Table attributes set
|
|||
|
//#define ATTRID_HVAC_PUMP_POWER_UNIT 0x0030
|
|||
|
/*** Power Unit attribute values ***/
|
|||
|
//#define HVAC_PUMP_POWER_UNIT_POWER_IN_WATTS 0x00
|
|||
|
//#define HVAC_PUMP_POWER_UNIT_POWER_IN_KILOWATTS 0x01
|
|||
|
|
|||
|
/**************************************************************************/
|
|||
|
/*** HVAC: Thermostat Cluster Attributes ***/
|
|||
|
/**************************************************************************/
|
|||
|
// Thermostat information attribute set
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_LOCAL_TEMPERATURE 0x0000
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_OUTDOOR_TEMPERATURE 0x0001
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_OCCUPANCY 0x0002
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_ABS_MIN_HEAT_SETPOINT_LIMIT 0x0003
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_ABS_MAX_HEAT_SETPOINT_LIMIT 0x0004
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_ABS_MIN_COOL_SETPOINT_LIMIT 0x0005
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_ABS_MAX_COOL_SETPOINT_LIMIT 0x0006
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_PI_COOLING_DEMAND 0x0007
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_PI_HEATING_DEMAND 0x0008
|
|||
|
|
|||
|
// Thermostat settings attribute set
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_LOCAL_TEMP_CALIBRATION 0x0010
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_OCCUPIED_COOLING_SETPOINT 0x0011
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_OCCUPIED_HEATING_SETPOINT 0x0012
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UNOCCUPIED_COOLING_SETPOINT 0x0013
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UNOCCUPIED_HEATING_SETPOINT 0x0014
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_MIN_HEAT_SETPOINT_LIMIT 0x0015
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_MAX_HEAT_SETPOINT_LIMIT 0x0016
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_MIN_COOL_SETPOINT_LIMIT 0x0017
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_MAX_COOL_SETPOINT_LIMIT 0x0018
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_MIN_SETPOINT_DEAD_BAND 0x0019
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_REMOTE_SENSING 0x001A
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_CTRL_SEQ_OF_OPER 0x001B
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_SYSTEM_MODE 0x001C
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_ALAM_MASK 0x001D
|
|||
|
/*** Remote Sensing attribute values ***/
|
|||
|
#define HVAC_THERMOSTAT_REMOTE_SENSING_LOCAL_TEMPERATURE 0x0001
|
|||
|
#define HVAC_THERMOSTAT_REMOTE_SENSING_OUTDOOR_TEMPERATURE 0x0002
|
|||
|
#define HVAC_THERMOSTAT_REMOTE_SENSING_OCCUPANCY 0x0004
|
|||
|
/*** Control Sequence of Operation attribute values ***/
|
|||
|
#define HVAC_THERMOSTAT_CTRL_SEQ_OF_OPER_COOLING_ONLY 0x00
|
|||
|
#define HVAC_THERMOSTAT_CTRL_SEQ_OF_OPER_COOLING_WITH_REHEAT 0x01
|
|||
|
#define HVAC_THERMOSTAT_CTRL_SEQ_OF_OPER_HEATING_ONLY 0x02
|
|||
|
#define HVAC_THERMOSTAT_CTRL_SEQ_OF_OPER_HEATING_WITH_REHEAT 0x03
|
|||
|
#define HVAC_THERMOSTAT_CTRL_SEQ_OF_OPER_COOLING_HEATING 0x04
|
|||
|
#define HVAC_THERMOSTAT_CTRL_SEQ_OF_OPER_COOLING_HEATING_WITH_REHEAT 0x05
|
|||
|
/*** System Mode attribute values ***/
|
|||
|
#define HVAC_THERMOSTAT_SYSTEM_MODE_OFF 0x00
|
|||
|
#define HVAC_THERMOSTAT_SYSTEM_MODE_AUTO 0x01
|
|||
|
#define HVAC_THERMOSTAT_SYSTEM_MODE_COOL 0x03
|
|||
|
#define HVAC_THERMOSTAT_SYSTEM_MODE_HEAT 0x04
|
|||
|
#define HVAC_THERMOSTAT_SYSTEM_MODE_EMERGENCY_HEATING 0x05
|
|||
|
#define HVAC_THERMOSTAT_SYSTEM_MODE_PRECOOLING 0x06
|
|||
|
#define HVAC_THERMOSTAT_SYSTEM_MODE_FAN_ONLY 0x07
|
|||
|
/*** Alarm Mask attribute values ***/
|
|||
|
#define HVAC_THERMOSTAT_INITIALIZATION_FAILURE 0x01
|
|||
|
#define HVAC_THERMOSTAT_HARDWARE_FAILURE 0x02
|
|||
|
#define HVAC_THERMOSTAT_SELF_CALIBRATION_FAILURE 0x03
|
|||
|
|
|||
|
// command IDs received by Server
|
|||
|
#define COMMAND_THERMOSTAT_SETPOINT_RAISE_LOWER 0x00
|
|||
|
|
|||
|
// Mode field values for the setpoint raise/lower command
|
|||
|
#define HVAC_THERMOSTAT_MODE_HEAT 0x00
|
|||
|
#define HVAC_THERMOSTAT_MODE_COOL 0x01
|
|||
|
#define HVAC_THERMOSTAT_MODE_BOTH 0x02
|
|||
|
|
|||
|
/**************************************************************************/
|
|||
|
/*** HVAC: Fan Control Cluster Attributes ***/
|
|||
|
/**************************************************************************/
|
|||
|
// Fan Control attribute set
|
|||
|
#define ATTRID_HVAC_FAN_CTRL_FAN_MODE 0x0000
|
|||
|
#define ATTRID_HVAC_FAN_CTRL_FAN_SEQUENCE 0x0001
|
|||
|
/*** Fan Mode attribute values ***/
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_OFF 0x00
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_LOW 0x01
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_MEDIUM 0x02
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_HIGH 0x03
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_ON 0x04
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_AUTO 0x05
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_SMART 0x06
|
|||
|
/*** Fan Mode Sequence attribute values ***/
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_SEQ_LOW_MED_HI 0x00
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_SEQ_LOW_HI 0x01
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_SEQ_LOW_MED_HI_AUTO 0x02
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_SEQ_LOW_HI_AUTO 0x03
|
|||
|
#define HVAC_FAN_CTRL_FAN_MODE_SEQ_ON_AUTO 0x04
|
|||
|
|
|||
|
/**************************************************************************/
|
|||
|
/*** HVAC: Dehumidifcation Control Cluster Attributes ***/
|
|||
|
/**************************************************************************/
|
|||
|
// Dehumidifcation Control Information attribute set
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_RELATIVE_HUMIDITY 0x0000
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_DEHUMID_COOLING 0x0001
|
|||
|
|
|||
|
// Dehumidifcation Control Settings attribute set
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_RHDEHUMID_SETPOINT 0x0010
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_RELATIVE_HUMIDITY_MODE 0x0011
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_DEHUMID_LOCKOUT 0x0012
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_DEHUMID_HYSTERESIS 0x0013
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_DEHUMID_MAX_COOL 0x0014
|
|||
|
#define ATTRID_HVAC_DEHUMIDIFICATION_CTRL_RELATIVE_HUMIDITY_DISPLAY 0x0015
|
|||
|
/*** Relative Humidity Mode attribute values ***/
|
|||
|
#define HVAC_DEHUMIDIFICATION_CTRL_RELATIVE_HUMIDITY_MEASURED_LOCALLY 0x00
|
|||
|
#define HVAC_DEHUMIDIFICATION_CTRL_RELATIVE_HUMIDITY_UPDATED_OVER_NET 0x00
|
|||
|
/*** Dehumidification Lockout attribute values ***/
|
|||
|
#define HVAC_DEHUMIDIFICATION_CTRL_DEHIMID_NOT_ALLOWED 0x00
|
|||
|
#define HVAC_DEHUMIDIFICATION_CTRL_DEHIMID_ALLOWED 0x01
|
|||
|
/*** Relative Humidity Display attribute values ***/
|
|||
|
#define HVAC_DEHUMIDIFICATION_CTRL_RELATIVE_HUMIDITY_NOT_DISPLAYED 0x00
|
|||
|
#define HVAC_DEHUMIDIFICATION_CTRL_RELATIVE_HUMIDITY_DISPLAYED 0x01
|
|||
|
|
|||
|
/**************************************************************************/
|
|||
|
/*** HVAC: Thermostat User Interface Config Cluster Attributes ***/
|
|||
|
/**************************************************************************/
|
|||
|
// Thermostat User Interface Config attribute set
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_CONFIG_TEMP_DISPLAY_MODE 0x0000
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_CONFIG_KEYPAD_LOCKOUT 0x0001
|
|||
|
/*** Display Mode attribute values ***/
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_CONFIG_DISPLAY_MODE_IN_C 0x00
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_CONFIG_DISPLAY_MODE_IN_F 0x01
|
|||
|
|
|||
|
/*** Keypad Lockout attribute values ***/
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_KEYPAD_NO_LOCOUT 0x00
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_KEYPAD_LEVEL1_LOCOUT 0x01
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_KEYPAD_LEVEL2_LOCOUT 0x02
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_KEYPAD_LEVEL3_LOCOUT 0x03
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_KEYPAD_LEVEL4_LOCOUT 0x04
|
|||
|
#define ATTRID_HVAC_THERMOSTAT_UI_KEYPAD_LEVEL5_LOCOUT 0x05
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
* VARIABLES
|
|||
|
*/
|
|||
|
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
* MACROS
|
|||
|
*/
|
|||
|
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
* TYPEDEFS
|
|||
|
*/
|
|||
|
|
|||
|
/*** ZCL HVAC Thermostat Cluster: Setpoint Raise/Lower Cmd payload ***/
|
|||
|
typedef struct
|
|||
|
{
|
|||
|
uint8 mode; // which setpoint is to be configured
|
|||
|
int8 amount; // amount setpoint(s) are to be increased (or decreased) by, in steps of 0.1<EFBFBD>C
|
|||
|
} zclCmdThermostatSetpointRaiseLowerPayload_t;
|
|||
|
|
|||
|
// This callback is called to process a Setpoint Raise/Lower command
|
|||
|
// mode - which setpoint to be configured
|
|||
|
// amount - the amount the setpoints are to be increased (or decreased) by, in steps of 0.1<EFBFBD>C
|
|||
|
typedef void (*zclHVAC_SetpointRaiseLower_t)( zclCmdThermostatSetpointRaiseLowerPayload_t *pCmd );
|
|||
|
|
|||
|
// Register Callbacks table entry - enter function pointers for callbacks that
|
|||
|
// the application would like to receive
|
|||
|
typedef struct
|
|||
|
{
|
|||
|
zclHVAC_SetpointRaiseLower_t pfnHVAC_SetpointRaiseLower;
|
|||
|
} zclHVAC_AppCallbacks_t;
|
|||
|
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
* VARIABLES
|
|||
|
*/
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
* FUNCTIONS
|
|||
|
*/
|
|||
|
|
|||
|
/*
|
|||
|
* Register for callbacks from this cluster library
|
|||
|
*/
|
|||
|
extern ZStatus_t zclHVAC_RegisterCmdCallbacks( uint8 endpoint, zclHVAC_AppCallbacks_t *callbacks );
|
|||
|
|
|||
|
/*
|
|||
|
* Send a Setpoint Raise/Lower Command
|
|||
|
*/
|
|||
|
ZStatus_t zclHVAC_SendSetpointRaiseLower( uint8 srcEP, afAddrType_t *dstAddr,
|
|||
|
uint8 mode, int8 amount,
|
|||
|
uint8 disableDefaultRsp, uint8 seqNum );
|
|||
|
|
|||
|
/*********************************************************************
|
|||
|
*********************************************************************/
|
|||
|
|
|||
|
#ifdef __cplusplus
|
|||
|
}
|
|||
|
#endif
|
|||
|
|
|||
|
#endif /* ZCL_HVAC_H */
|